Pinless Moisture Meter

ET140

  • Pinless Moisture Meter detects relative moisture from leaks and flooding, and measures relative moisture content in building materials
  • Nondestructive detection of relative moisture content using Electromagnetic field (EMF) technology
  • Select materials with mode button: drywall, masonry, hardwood, and softwood (Calibrated for these materials only)
  • Detects relative moisture content up to 3/4-Inch (1.9 cm) deep
  • Easy viewing with bright reverse-contrast display with nine LED bars to indicate relative moisture range
  • Hold, Low battery, and Auto-Power off functions
  • Built to withstand a 6.6 foot (2 m) drop
  • Includes meter, 9V battery, and instruction manual
ce Product Icon
drop_protection-2m Product Icon
Videos
Downloads
Images
High-Res JPG
PNG
Interactive Catalog

7MÊÓƵ ET140 Moisture Meter is designed to non-invasively detect hidden relative moisture content up to 3/4-Inch (19 mm) depth. Easily select between materials with mode button to test surface of drywall, masonry, hardwood, and softwood. The ET140 has easy viewing with bright, reverse-contrast display and LED bar graph.

Specifications
Type:
Pinless Moisture Meter
Application:
Calibrated for Drywall, Masonry, Hardwood, Softwood Only
Special Features:
Audible Alert, Auto-Power Off, Visual Notification
Display:
Bright Reverse-Contrast Display and a Nine LED Bar Graph
Display Resolution:
0.1%
External Electrode:
None
Sensor Size:
1.25'' x 2'' (3.5 x 5 cm)
Sensing Depth:
0.75'' (1.9 cm)
Moisture Reading Range:
0 to 100%
Accuracy:
+/-4%
Measurable Materials:
Drywall, Masonry, Hardwood, Softwood
Batteries:
1 x 9V
Drop Protection:
6.6' (2 m)
Included:
Moisture Meter; 1 x 9V Battery; Instruction Manual
Material:
ABS Plastic
Overall Length:
6'' (15.2 cm)
Overall Height:
1'' (2.5 cm)
Overall Width:
2.5'' (6.4 cm)
Weight:
7 oz (200 g)
UPC:
092644692734
Additional Information
Warnings
  • Always wear approved eye protection.
  • Never use on or near live electrical circuits. NOT insulated. Will NOT protect against electrical shock.
  • Read, understand and follow all instructions, cautions and warnings attached to and/or packed with all test and measurement devices before each use.